Lanpu.Precision

Aerospace Nozzle Adapter — 5-Axis, AS9102 First Article

A contoured aluminium nozzle adapter machined complete in one 5-axis setup, with an AS9102 first-article report and full traceability to the melt lot.

Aerospace Nozzle Adapter — 5-Axis, AS9102 First Article

Part specification

Industry
Aerospace & Defence
Process
5-Axis Machining
Material
Aluminium 7075-T651
Tolerance
⌀0.02 mm true position
Finish
Chromate conversion, MIL-DTL-5541
Quantity
120 / year
Lead time
22 working days

Customer details withheld under NDA.

Get a quote

Challenge

The adapter has features on five faces with true position between them specified at ⌀0.05 mm. Machining it in three setups on a 3-axis machine consumed the entire tolerance in fixture repeatability before any cutting error was counted.

Solution

Machined complete in one 5-axis setup on a trunnion machine, with the CAM programme simulated against the full kinematic model including fixture and holders. The CMM programme measures from the same datum scheme the CAM used, so the report reflects how the part was actually made.

Result

True position measures within ⌀0.02 mm across all five faces — less than half the specified tolerance. AS9102 Forms 1, 2 and 3 were accepted without comment on the first submission, and the part moved to production release three weeks earlier than planned.

Aerospace Nozzle Adapter — 5-Axis, AS9102 First Article — 1
Aerospace Nozzle Adapter — 5-Axis, AS9102 First Article — 2

Why one setup mattered

The tolerance budget was ⌀0.05 mm across five faces. A three-setup process on a 3-axis machine consumes roughly 0.03 mm in fixture repeatability alone, leaving almost nothing for the cutting process.

Machining all five faces in one setup removes that consumption entirely: the only errors remaining are machine positioning and tool deflection, both of which are an order of magnitude smaller.

Documentation

  • AS9102 Form 1 — part accountability
  • AS9102 Form 2 — raw material and special process accountability
  • AS9102 Form 3 — characteristic accountability, measured value for every ballooned feature
  • EN 10204 3.1 certificate, PMI verified on receipt
  • Chromate conversion certificate to MIL-DTL-5541 Type II

Send us your drawing today